Welcome To Teledyne Monitor Labs

Home    Company Information    Contact Us

Corporate Information

Products
Continuous Emission
    Monitoring Systems
    In situ

        SM®8200

        SM®425

    Standard Extractive
    Dilution Extractive

Flow Monitors

    UltraFlow 150

Gas Monitors

    T SERIES

Opacity Monitors

    LightHawk®

Particulate Monitors

    LaserHawk®

    LaserHawk® 360P

Software

    RegPerfect®

    RegPerfect.net

Useful Information
Trade Shows
Quality Policy

Links

Support
Customer Service

Service
Opacity Attenuator (Filter)
    Certification

Call Center

Training
    Hardware Training
    Software Training

Product Status

Manuals

Firmware Downloads

Sample Specifications

Contact Us
Visiting Our Facility

Representatives and
   Distributors


Where to Stay

Career Opportunities


Terms and Conditions

Teledyne Monitor Labs is a leading supplier of environmental monitoring
 instrumentation, systems and software

 
Installation Checklist UltraFlow 150 

    

* Your order cannot be scheduled for production until accurate information is
provided for all fields marked with an asterisk.

 
» Download this Document
» How to Use this Document
1.  CUSTOMER CONTACT INFORMATION
Name:    *
Title:
Company:    *
Phone:    *
Fax:
Email:    *
Stack Identification:    *

(Limited to 10 characters)

Upgrade or Replacement of a UF100?  Yes No    *
If yes, UF100 Serial#

2.  APPLICATION INFORMATION
Monitor will be used for: compliance Process Control    *
Process Type: *
Measurement Location Elevation (above mean sea level): Feet Meters *
Wet Scrubber: Yes No   *
Selective Catalytic Reduction (SCR): Yes No   *
Redundancy, two separate TIEs on the stack: Yes No   *
X-Pattern, two measurement paths with one TIE: Yes No   *

3.  PROCESS VARIABLES
Typical Temperature:  * Degrees F Degrees C
Maximum Velocity for Certification: * Feet/Sec  Meters/sec
Minimum Velocity for Certification: * Feet/Sec  Meters/sec
Typical %H2O by volume: *
Typical %O2 by volume: *
Typical %CO2 by volume: *
Typical SO2 ppm:
Typical NOx ppm:
Typical HCL ppm:
Other Gases:

MAXIMUM TEMPERATURE     *
 -40 to 250F (-40 to 121C)  451 to 500F (233 to 260C)60C)
 251 to 300F (122 to 149C)  501 to 550F (261 to 287C)
 301 to 350F (150 to 176C)  551 to 600F (288 to 315C)
 351 to 400F (177 to 204C)  601 to 650F (316 to 343C)
 401 to 450F (205 to 232C)  >650F (> 343C) Consult Factory


PROCESS PRESSURE     *
 -30 TO -15 in. H2O (-7.47 to -3.745 kPa)  +10 to 15in. H2O (+2.49 to +3.745 kPa)
 -15 to -5in. H2O (-3.745 to -1.245 kPa)  +15 to +20in. H2O (+3.745 to +4.98 kPa)
 -5 to +5in. H2O (-1.245 to +1.245 kPa)  Other, Consult Factory
 +5 to +10in. H2O (+1.245 to +2.49 kPa)  


PARTICULATE     *
  <=3000 mg/m3
  > 3000 mg/m3


4.  GEOMETRY OF STACK OR DUCT   

 

Orientation:    * Vertical Horizontal
Shape:    * Round Rectangular


INSIDE DIAMETER OF STACK OR DUCT     * 

 

 

If Round

If Rectangular

Depth

If Rectangular

Width

 
Upstream:          *

Feet  Meters
Downstream:     *

Feet  Meters

All geometry calculations will be preformed assuming the transducers will be mounted across the “Width” dimension. (See Attachment B).


OFFSET       *

 

This is the upstream vs. downstream displacement between the two transducers. The
OFFSET will provide the information necessary to calculate the mounting angle. After reviewing the
information in this checklist, Teledyne Monitor Labs will recommend the optimum OFFSET distance.

 

Feet  Meters


THICKNESS OF STACK WALLS     *

 

 

 

Upstream

Downstream

 
Inner liner wall thickness *

in ft Meters
Annular space thickness*

in ft Meters
Outer shell wall thickness*

in ft Meters

Please note below any Mounting Tube Installation or other known stack or duct characteristics that
may be important for installation or factory calibration.
Examples:
• Structural bracing.
• Existing sampling probes located near or between the proposed locations of the transducers.
• Reuse of existing ports, etc.

5.  DISTANCE FROM DISTURBANCES      *

 

This is imperative to judge potential flow pattern issues in the stack or duct.

Downstream * Feet Meters
Upstream * Feet Meters
Multiple inlets to the stack or duct?* Yes   No
Comments:
 

6.  INPUTS AND OUTPUTS

BAROMETRIC PRESSURE TRANSDUCER OPTIONS    *
I do NOT want to use any Barometric Pressure Transducer 

I do want to use the Barometric Pressure Transducer and I wish to purchase the Pressure Sensor from Teledyne Monitor Labs.      

I DO want to use the Barometric Pressure Transducer and I will supply my own  

See scaling below

 

Type

Scaling

  Value @ 1V or 4mA Value @ 5V or 20mA
Voltage
Current

EXTERNAL TEMPERATURE OPTIONS
I do NOT want to use the External Temperature Option.  I prefer to use the temperature calculated by the UltraFlow.

I DO want to use the External Temperature Option and I wish to purchase a temperature sensor from Teledyne Monitor Labs, Inc.

I DO want to use the External Temperature Option and I will supply my own.

(See scaling below).


Type

Scaling

  Value @ 1V or 4mA Value @ 5V or 20mA
Voltage

Current
1000 ohm RTD    
100 ohm RTD    

7.  SYSTEM CONFIGURATION    *
 Direct Interface Enhanced Remote Panel

If you selected the DIRECT INTERFACE Configuration, fill out this section

A detailed list of the available Analog and Digital Outputs is included in . Please list your selections in the tables below.
Analog Output Channel Number Value at 4 mA. Value at 20 mA. Description Units Display Calibration Data Y/N

1

2


Digital Output Number Description
1
2


THIS IS THE END OF THE DIRECT INTERFACE CONFIGURATION

IF YOU SELECTED THE ENHANCED REMOTE PANEL CONFIGURATION, COMPLETE THIS SECTION.

A detailed list of the available Analog and Digital Outputs is included in . Please list your selections in the tables below.
Analog Output Channel Number Value at4 mA. Value at20 mA. Description Units Display Calibration Data?

1

2

3

4

 
Digital Output Number

Description

1
2
3
4
5
6
7
8


ETHERNET MODULE SETUP
Use a Dynamic IP address.
Use a Static Internet Provider address.  If yes, please supply the information below:
Static IP Address
Subnet Mask
Default Gateway
Enter code to confirm submission
Confirmation:   Validation Enter Confirmation Code:   *
 

THIS IS THE END OF THE ENHANCED REMOTE PANEL CONFIGURATION

 


Home | Warranty | Terms of Use | Service & Support | Products | Contact Us

Copyright © 2016 Teledyne Technologies Incorporated. All rights reserved.
35 Inverness Drive East - Englewood, CO 80112